Source: 300 kV, CFEG Filter: 10 eV Detector: Falcon 4 Sample: Mouse Apoferritin Grids: Quantifoil UltraAu 1.2/1.3 Exposures: 2 shots/hole Exposure Time: 1.81 sec Total Dose: 40 e/A^2 Total Frames: 434 Cs: 2.7 mm Pixel Size: 0.457 A/px Target Defocus Range: 0.3 - 0.9 um (auto-focus every 6 um) Total Number of Movies: 3370 Gain reference: gainImage_8k_defMasked.mrc NOTE: 0.457 A/px is the final calibrated value. Data processing was started assuming 0.452 A/px and the (apparent) Cs was refined to 2.5653 mm. "final_shiny.star" contains these values. The FSC curve was re-scaled to the right pixel size in the PostProcess. The pixel values should be divided, not multiplied, by the gain reference. See explanations in the EER version of RELION (https://github.com/3dem/relion/tree/devel-eer). * TIME STAMPS OF LIQUID NITROGEN REFILS 2020-02-25 06:53:34 2020-02-25 13:59:46 2020-02-25 20:56:24 2020-02-25 21:02:18 2020-02-26 04:09:00 2020-02-26 11:12:33 * DATA COLLECTION BATCHES GROUPED BY COLD FEG FLUSHING 2020-02-25 06:36:48 2020-02-25 13:03:51 2020-02-26 00:16:58 2020-02-26 05:23:02 2020-02-26 10:28:05 2020-02-26 22:01:11