<entry xmlns="http://pdbe.org/empiar" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="https://ftp.ebi.ac.uk/pub/databases/emtest/empiar/schema/empiar.xsd" accessionCode="EMPIAR-13721" schemaVersion="0.65" public="true">
    <admin>
        <currentStatus>REL</currentStatus>
        <keyDates>
            <depositionDate>2025-10-17</depositionDate>
            <releaseDate>2026-10-06</releaseDate>
            <updateDate>2026-10-06</updateDate>
        </keyDates>
        <title>Cryo-EM structure of the hTUT4_mini:Lin28A:pre-let-7g_UUU complex</title>
        <correspondingAuthor private="true">
            <authorORCID>0000-0002-7374-3898</authorORCID>
            <firstName>Kozo</firstName>
            <lastName>Tomita</lastName>
            <organization type="academic">Department of Computational Biology and Medical Sciences, The University of Tokyo</organization>
            <street>5-1-5 Kashiwanoha</street>
            <townOrCity>Kashiwa-shi, Chiba-ken</townOrCity>
            <country>Japan</country>
            <postOrZipCode>277-8562</postOrZipCode>
        </correspondingAuthor>
        <principalInvestigator private="true">
            <authorORCID>0000-0002-7374-3898</authorORCID>
            <firstName>Kozo</firstName>
            <lastName>Tomita</lastName>
            <organization type="academic">Department of Computational Biology and Medical Sciences, The University of Tokyo</organization>
            <street>5-1-5 Kashiwanoha</street>
            <townOrCity>Kashiwa-shi, Chiba-ken</townOrCity>
            <country>Japan</country>
            <postOrZipCode>277-8562</postOrZipCode>
        </principalInvestigator>
        <authorsList>
            <author>Han X</author>
            <author authorORCID="0000-0002-6970-8758">Yamashita S</author>
            <author authorORCID="0000-0002-7374-3898">Tomita K</author>
        </authorsList>
        <grantSupport>
            <grantReference>
                <fundingBody></fundingBody>
                <code></code>
                <country></country>
            </grantReference>
        </grantSupport>
        <datasetSize units="TB">7.7</datasetSize>
        <entryDOI>10.6019/EMPIAR-13721</entryDOI>
        <experimentType>EMDB</experimentType>
        <scale>molecule</scale>
    </admin>
    <crossReferences>
        <relatedEMDBEntries>
            <emdbEntry>EMD-65642</emdbEntry>
            <emdbEntry>EMD-65643</emdbEntry>
        </relatedEMDBEntries>
        <citationList>
            <universalCitation>
                <journalCitation published="true" preprint="false">
                    <author order="1">Han X</author>
                    <author authorORCID="0000-0002-6970-8758" order="2">Yamashita S</author>
                    <author authorORCID="0000-0002-7374-3898" order="3">Tomita K</author>
                    <title>Mechanistic insights into Lin28-dependent oligo-uridylylation of pre-let-7 by TUT4</title>
                    <journal>Nucleic acids research</journal>
                    <journalAbbreviation>Nucleic Acids Res</journalAbbreviation>
                    <country></country>
                    <issue>1</issue>
                    <volume>54</volume>
                    <year>2026</year>
                    <language>English</language>
                    <externalReferences type="doi">10.1093/nar/gkaf1421</externalReferences>
                    <externalReferences type="pubmed">41521656</externalReferences>
                </journalCitation>
            </universalCitation>
        </citationList>
    </crossReferences>
    <imageSet>
        <name>20240719_Tomita_TUT4_3_data</name>
        <directory>/data</directory>
        <category>micrographs - multiframe</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>4296</numImagesOrTiltSeries>
        <framesPerImage>50</framesPerImage>
        <frameRange>
            <frameRangeMin>1</frameRangeMin>
            <frameRangeMax>50</frameRangeMax>
        </frameRange>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>5760</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>4092</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>- Microscope: FEI TITAN Krios
- Acceleration voltage (kV): 300
- Spherical aberration (Cs) : 2.7
- Defocus (nm): -800 to -1800
- Magnification:105000
- Detector: Gatan K3 BIOQUANTUM
- Average electron dose per image (e-/A2): 50
- Number of frames per image: 50
- The pixel size in the image header (1 Å/px) is wrong. 0.83 Å/px is the calibrated value.
- Please use 'gain.mrc' as a gain reference with y-flipping for CryoSPARC.</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>20240724_Tomita_TUT4_2_data</name>
        <directory>/data</directory>
        <category>micrographs - multiframe</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>9977</numImagesOrTiltSeries>
        <framesPerImage>50</framesPerImage>
        <frameRange>
            <frameRangeMin>1</frameRangeMin>
            <frameRangeMax>50</frameRangeMax>
        </frameRange>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>5760</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>4092</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>- Microscope: FEI TITAN Krios
- Acceleration voltage (kV): 300
- Spherical aberration (Cs) : 2.7
- Defocus (nm): -800 to -1800
- Magnification:105000
- Detector: Gatan K3 BIOQUANTUM
- Average electron dose per image (e-/A2): 50
- Number of frames per image: 50
- The pixel size in the image header (1 Å/px) is wrong. 0.83 Å/px is the calibrated value.
- Please use 'gain.mrc' as a gain reference with y-flipping for CryoSPARC.</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>20240808_Tomita_TUT4_1_data</name>
        <directory>/data</directory>
        <category>micrographs - multiframe</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>9818</numImagesOrTiltSeries>
        <framesPerImage>50</framesPerImage>
        <frameRange>
            <frameRangeMin>1</frameRangeMin>
            <frameRangeMax>50</frameRangeMax>
        </frameRange>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>5760</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>4092</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>- Microscope: FEI TITAN Krios
- Acceleration voltage (kV): 300
- Spherical aberration (Cs) : 2.7
- Defocus (nm): -800 to -1800
- Magnification:105000
- Detector: Gatan K3 BIOQUANTUM
- Average electron dose per image (e-/A2): 50
- Number of frames per image: 50
- The pixel size in the image header (1 Å/px) is wrong. 0.83 Å/px is the calibrated value.
- Please use 'gain.mrc' as a gain reference with y-flipping for CryoSPARC.</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>20241129_Tomita_TUT4_gUUU_Au_1_data</name>
        <directory>/data</directory>
        <category>micrographs - multiframe</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>6382</numImagesOrTiltSeries>
        <framesPerImage>50</framesPerImage>
        <frameRange>
            <frameRangeMin>1</frameRangeMin>
            <frameRangeMax>50</frameRangeMax>
        </frameRange>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>5760</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>4092</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>- Microscope: FEI TITAN Krios
- Acceleration voltage (kV): 300
- Spherical aberration (Cs) : 2.7
- Defocus (nm): -800 to -1800
- Magnification:105000
- Detector: Gatan K3 BIOQUANTUM
- Average electron dose per image (e-/A2): 50
- Number of frames per image: 50
- The pixel size in the image header (1 Å/px) is wrong. 0.83 Å/px is the calibrated value.
- Please use 'gain.mrc' as a gain reference with y-flipping for CryoSPARC.</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
    <imageSet>
        <name>20241129_Tomita_TUT4_gUUU_Au_2_data</name>
        <directory>/data</directory>
        <category>micrographs - multiframe</category>
        <headerFormat>TIFF</headerFormat>
        <dataFormat>TIFF</dataFormat>
        <numImagesOrTiltSeries>7290</numImagesOrTiltSeries>
        <framesPerImage>50</framesPerImage>
        <frameRange>
            <frameRangeMin>1</frameRangeMin>
            <frameRangeMax>50</frameRangeMax>
        </frameRange>
        <voxelType>UNSIGNED BYTE</voxelType>
        <dimensions>
            <imageWidth>5760</imageWidth>
            <pixelWidth>variable</pixelWidth>
            <imageHeight>4092</imageHeight>
            <pixelHeight>variable</pixelHeight>
        </dimensions>
        <details>- Microscope: FEI TITAN Krios
- Acceleration voltage (kV): 300
- Spherical aberration (Cs) : 2.7
- Defocus (nm): -800 to -1800
- Magnification:105000
- Detector: Gatan K3 BIOQUANTUM
- Average electron dose per image (e-/A2): 50
- Number of frames per image: 50
- The pixel size in the image header (1 Å/px) is wrong. 0.83 Å/px is the calibrated value.
- Please use 'gain.mrc' as a gain reference with y-flipping for CryoSPARC.</details>
        <segmentationList/>
        <micrographsFilePattern></micrographsFilePattern>
        <pickedParticlesFilePattern></pickedParticlesFilePattern>
        <pickedParticlesDirectory></pickedParticlesDirectory>
    </imageSet>
</entry>
